What are the default calibration points?
| IPN | English Product Name |
| CADT01P7 | Calibration internal temperature sensor at 0 °C (1-point calibration) |
| CADT03P1 | Calibration internal temperature sensor at -20 °C / +5 °C / +40 °C (3-point calibration) |
| CADT53PW | Calibration internal temperature sensor not older than 5 months at -20 °C / +5 °C / +40 °C (3-point calibration) |
| CADT93PS | Calibration internal temperature sensor not older than 9 months at -20 °C / +5 °C / +40 °C (3-point calibration) |
| CADT03DA | Calibration internal temperature sensor according to DAkkS at -20 °C / +5 °C / +40 °C (3-point calibration) |
| CADAD010 | Calibration ADC for devices with external Probe at -196 °C / -80 °C / -20 °C / +0 °C / +60 °C |
| CADAD05W | Calibration ADC for devices with external Probe not older than 5 months at -196 °C / -80 °C / -20 °C / +0 °C / +60 °C |
| CADAD09S | Calibration ADC for devices with external Probe not older than 9 months at -196 °C / -80 °C / -20 °C / +0 °C / +60 °C |
| CADAD02Z | Calibration ADC for devices with external Probe according to DAkkS at -196 °C / -80 °C / -20 °C / +0 °C / +60 °C |
| CADS01X2 | Calibration internal temperature sensor with alternative measuring point |
| CADS15XP | Batch calibration internal temperature sensor with alternative measuring point for up to 15 devices |
| CAPS01P1 | Calibration Probe at 0 °C (1-point calibration) |
| CAPF03D1 | Calibration Probe frozen at -20 °C / +0 °C / +40 °C (3-point calibration) |
| CAPF53PM | Calibration Probe frozen not older than 5 months at -20 °C / +0 °C / +40 °C (3-point calibration) |
| CAPF93PG | Calibration Probe frozen not older than 9 months at -20 °C / +0 °C / +40 °C (3-point calibration) |
| CAPF03PS | Calibration Probe frozenaccording to DAkkS at -20 °C / +0 °C / +40 °C (3-point calibration) |
| CAPD03PY | Calibration Probe for ultra-deep-freezing at -80 °C / +0 °C / +40 °C (3-point calibration) |
| CAPD53PT | Calibration Probe for ultra-deep-freezing not older than 5 months at -80 °C / +0 °C / +40 °C (3-point calibration) |
| CAPD93PP | Calibration Probe for ultra-deep-freezing not older than 9 months at -80 °C / +0 °C / +40 °C (3-point calibration) |
| CAPD03D7 | Calibration Probe for ultra-deep-freezing according to DAkkS at -80 °C / +0 °C / +40 °C (3-point calibration) |
| CAPC03P1 | Calibration Probe for cryogenics at -196 °C / +0 °C / +40 °C (3-point calibration) |
| CAPC53PW | Calibration Probe for cryogenics not older than 5 months at -196 °C / +0 °C / +40 °C (3-point calibration) |
| CAPC93PS | Calibration Probe for cryogenics not older than 9 months at -196 °C / +0 °C / +40 °C (3-point calibration) |
| CAPC03DA | Calibration Probe for cryogenics according to DAkkS at -196 °C / +0 °C / +40 °C (3-point calibration) |
| CAP001X2 | Calibration Probe with alternative measuring point |
| CAP030X2 | Batch calibration Probes for alternative measuring point for up to 30 Probes |
| CADH03PV | Calibration internal humidity sensor at 25 %rH / 50 %rH / 75 %rH (3-point calibration) |
| CADH01XT | Calibration internal humidity sensor with alternative measuring point |